Product Detail
- Product: P4KE TVS diode.
- Power: 400W peak pulse.
- Package: axial leaded.
- Selection: VRWM and polarity.
Product Description
This P4KE TVS diode page is for buyers selecting 400W axial surge protection for DC rails, control lines and general equipment boards. You can compare P4KE by reverse working voltage, breakdown range, clamping voltage, peak pulse current, direction type, package fit and expected surge waveform. It is a protection part, not a rectifier. Lian Tuo helps you decide whether P4KE has enough pulse margin or whether P6KE, 1.5KE or another TVS family should be tested. That keeps P4KE tied to 400W surge protection. It also avoids confusing a TVS part with a rectifier.
Our P4KE TVS Diode Options
| P4KE TVS Diode | 400W axial transient suppressor for compact surge protection paths. |
| P4KE Unidirectional TVS Diode | Choice for DC rails where polarity and clamping direction matter. |
| P4KE Bidirectional TVS Diode | Option for AC or signal lines needing symmetrical surge response. |
| 400W TVS Diode | Power-class route when surge energy is moderate and space is limited. |
| P4KE Equivalent Diode | Replacement support based on VRWM, VBR, VC and package fit. |
Feature Box
- 400W ClassPulse rating fits moderate surge events.
- Voltage ChoiceVRWM and VBR guide model selection.
- Clamp ReviewVC must protect downstream circuits.
- Direction OptionsUni and bidirectional types are available.
Start With VRWM
A P4KE TVS diode should be selected from the normal working voltage of the line. VRWM must sit above the steady operating voltage, while breakdown and clamping values must still protect the circuit. This prevents nuisance conduction during normal operation. It also avoids confusing a TVS part with a rectifier.
Check The Clamp Level
The clamping voltage decides how much surge reaches the protected IC, rail or connector. A P4KE TVS diode should be compared by VC at the relevant pulse current, not only by part number. The absolute maximum rating of the protected component should guide the choice. That keeps P4KE tied to 400W surge protection.
Choose Direction Carefully
Unidirectional and bidirectional P4KE parts are not interchangeable in every circuit. A P4KE TVS diode for a DC rail usually needs polarity review, while AC or data-related lines may need bidirectional behavior. The schematic should decide the suffix. It also avoids confusing a TVS part with a rectifier. That keeps P4KE tied to 400W surge protection.
Compare Surge Energy
The 400W class can be enough for many board-level events, but stronger surge paths may need P6KE, 1.5KE or higher-power TVS families. Lian Tuo can compare the P4KE TVS diode against your pulse waveform and protection target. That keeps P4KE tied to 400W surge protection. It also avoids confusing a TVS part with a rectifier.
Treat It As Protection
A P4KE diode is often confused with rectifier families because it has an axial body. It should be treated as a transient voltage suppressor. The key data are VRWM, VBR, VC, peak pulse power and direction type, not rectifier recovery. It also avoids confusing a TVS part with a rectifier.
Vertical Product Applications
DC Power Rails
Use a P4KE TVS diode on DC power rails when the line needs moderate surge clamping and axial through-hole assembly. The selected VRWM should stay above the normal rail voltage while VC protects the downstream circuit. It also avoids confusing a TVS part with a rectifier. That keeps P4KE tied to 400W surge protection.
Control Board Inputs
Control board inputs can use P4KE when surge exposure is present but space and cost need a 400W class device. You should review line voltage, connector exposure and whether unidirectional or bidirectional protection is needed. That keeps P4KE tied to 400W surge protection. It also avoids confusing a TVS part with a rectifier.
General Equipment Protection
General equipment boards often need simple axial surge protection near connectors or rails. A P4KE TVS diode can fit when the surge waveform is moderate and the protected components tolerate the clamping voltage. It also avoids confusing a TVS part with a rectifier. That keeps P4KE tied to 400W surge protection.
Replacement TVS Orders
Replacement TVS orders should match the original suffix, voltage code and direction. Lian Tuo can help you compare a P4KE TVS diode with P6KE or 1.5KE alternatives when the old marking is incomplete. That keeps P4KE tied to 400W surge protection. It also avoids confusing a TVS part with a rectifier.
FAQ
How do I choose a P4KE TVS diode?
Start with the normal line voltage, required VRWM, breakdown range, clamping voltage, surge waveform, package and direction type. The P4KE TVS diode should protect the circuit without conducting during normal operation. It also avoids confusing a TVS part with a rectifier.
What does 400W mean for P4KE?
400W is the peak pulse power class under specified pulse conditions. It does not mean continuous power dissipation. You should compare the expected surge waveform and peak pulse current before approving a P4KE part. That keeps P4KE tied to 400W surge protection.
Can P4KE replace P6KE?
Only if the surge energy and electrical limits fit the lower 400W class. P6KE is a 600W family, so moving down to P4KE should be checked carefully against the actual protection requirement. It also avoids confusing a TVS part with a rectifier.
Should I choose unidirectional or bidirectional P4KE?
Use unidirectional parts for many DC rail protection cases where polarity is clear. Use bidirectional parts when the line needs symmetrical clamping. The schematic and protected interface should decide the direction type. That keeps P4KE tied to 400W surge protection.
What data helps quote P4KE?
Send VRWM, voltage code, direction type, package, quantity and application. If you know the surge waveform or protected IC rating, include it so the P4KE TVS diode can be checked against clamping needs. It also avoids confusing a TVS part with a rectifier.
Is P4KE a rectifier diode?
No. P4KE is a TVS diode family for transient voltage suppression. It is used for surge protection, so selection focuses on working voltage, breakdown voltage, clamping voltage and pulse power. That keeps P4KE tied to 400W surge protection. It also avoids confusing a TVS part with a rectifier.
Can P4KE protect power supplies?
Yes, when the power rail voltage and surge waveform fit the selected model. For harsher inputs or stronger surge tests, you may need P6KE, 1.5KE or higher-power TVS options instead. It also avoids confusing a TVS part with a rectifier.
Can Lian Tuo support P4KE equivalents?