The power supply passed every cold test and failed after eighteen minutes. Its 1N5408 also passed a handheld diode check as soon as the board returned to the bench. That is the awkward part of an intermittent open: the component can look healthy before and after the event. The useful evidence lives in the few seconds when the output actually disappears.

1N4007 rectifier arranged for a cold and hot continuity check

The Cold Meter Said The Diode Was Fine

This worked case used a 24 V supply feeding a 1.8 A load. At startup, the diode drop looked ordinary and the output was steady. After eighteen minutes, the output dipped for roughly 40 ms at a time. A panel meter barely moved; the oscilloscope showed missing current pulses.

The first temptation is to replace the diode. I would pause there. An internal bond can open when hot, but a cracked solder joint or lifted pad can produce the same symptom. Put one channel across the diode body and another across the complete path from copper to copper. If only the second trace jumps, the package may be innocent.

On this example, the cold diode reading was 0.58 V. During the failure, the copper-to-copper path briefly rose above 3 V while the diode body did not show a matching change. That moved the investigation toward the connection rather than the junction.

RL207 axial rectifier with separate package and solder-joint probes

Heat The Suspect Area, Not The Whole Board

A hot-air gun aimed at half the assembly tells you almost nothing. Warm the diode body, each lead, and each pad separately while current and output voltage are being recorded. Use the lowest airflow that gives a controlled temperature change. A thermocouple beside the test point is more useful than the number printed on the hot-air station.

The fault appeared when one solder fillet reached about 104 degrees Celsius. Heating the diode body alone to the same temperature did not reproduce it. Cooling that fillet restored the current pulse within seconds. That result still was not proof, but it gave the next inspection a specific place to start.

Under magnification, a dark ring was visible around the lead. Cross-sectioning is not always practical, so the production check also compared joint resistance while the board was flexed gently in its normal mounting direction. The suspect connection moved from 12 milliohms cold to intermittent readings above 0.8 ohm.

What Stayed In The Failure Log

Observation Worked Result What It Changed
Cold diode check 0.58 V and stable Did not clear an intermittent hot fault
Output waveform 40 ms missing-current events Provided a trigger for the failure
Local heating Fault near 104°C at one fillet Separated the joint from the diode body
Connection resistance 12 mΩ cold, above 0.8 Ω intermittently Made the cracked joint the primary suspect

A failure log should include the probe points and trigger condition, not only screenshots. Otherwise a later engineer cannot tell whether the 3 V event was measured across the silicon, one lead, or the whole current path.

1N5408 rectifier inspected after an intermittent open event

The Replacement Needed A Different Check

Reflowing the joint made the original board work, but it did not explain why the crack formed. Lead bending had placed the fillet under tension, and the diode body sat too close to the board. The repair would have returned if the mechanical detail stayed unchanged.

The revised build added lead relief and repeated the full current and temperature cycle on several boards. Forward loss, reverse voltage, surge current, and package temperature were checked again because a larger replacement can alter all four. A standard rectifier is not interchangeable with a fast recovery diode merely because both survive the DC meter test.

Useful references include the rectifier diode range, standard rectifiers, 1N4007, RL207, 1N5408, and 6A10. Switched supplies may also need the fast recovery diode range or the wider bridge rectifier range.

6A10 rectifier installed with lead relief for a repeat thermal test

Final Thoughts

An intermittent open has to be captured while it is happening. Compare voltage across the package with voltage across the complete connection, then move heat one small area at a time. Send that failure capture, current waveform, mounting photograph, and temperature record to Electronic Diode when you request replacement samples.

Questions From The Failure Review

Can A Diode Pass A Meter Test And Still Be Bad?

Yes. A bond, lead, or solder connection may open only under temperature, current, vibration, or mechanical stress.

How Do You Find An Intermittent Open?

Trigger the oscilloscope on the output disturbance and record current plus voltage across both the device and its complete connection.

Should You Heat The Whole Board?

Not first. Local heating and cooling give better location evidence. Record the actual test-point temperature and keep airflow controlled.

Can Reflowing The Joint Be The Final Fix?

Only after the crack cause is understood. Lead stress, pad damage, thermal cycling, solder process, and vibration can make the fault return.

When Should A Fast Recovery Diode Be Used?

Use it when the switching waveform requires controlled recovery. Match voltage, current, recovery, temperature, and package conditions rather than substituting by size.